Key Sourcing Takeaways
- Confirm the complete tool envelope and mounting space against the receiving press.
- Collect a current drawing, approved part and cavity-level defect history before the tool ships.
- Write the T1 acceptance criteria and identify any repair work before releasing a production order.
Mounting checks for an HCR compression mold
- Lift points and weight
- Parting face and vents
- Vacuum port
- Platen and clamp positions
- Ejector travel (if used)
Match the mold to the actual receiving press
Get the tool's measured length, width, closed height and weight. Ask for photos of each mounting face, all clamps and lifting points, and connections with a reference scale. Compare the approach and handling space with the receiving press. Youbang's HCR compression platens range from 400 × 400 to 650 × 650 mm. Use the actual machine drawing to check working clearance and bolt locations. For LSR, match the feed and cold-runner interfaces, cooling and control details, and any ejection or demolding mechanism.
Seven checks for a silicone mold transfer
| Check | Ask the outgoing factory for | Verify with the receiving factory | If something is off |
|---|---|---|---|
| 1. Envelope and mounting | Overall length, width and closed height, plus clamp and bolt drawings | Platen fit, opening and working space, hole positions and loading clearance | Review a dimensioned fit drawing and quote any mounting changes before shipping. |
| 2. Tool weight and lifting points | Tool weight, centers of gravity if available, and photos of rated lifting points and transport restraints | An approved lift and set-down plan using correctly rated equipment and identified lift points | Have qualified handling staff resolve missing weight, ratings or unsafe lifting points before moving the tool. |
| 3. Opening travel and ejection | Tool opening sequence, ejector pattern and stroke, and any manual demolding steps | Enough open clearance, matching pins and a safe stroke for removing the part | Agree mechanical changes and validate the complete motion before molding. |
| 4. Vacuum and process connections | Vacuum port details, heater and sensor specs, or LSR cold-runner connections and controls | Match ports, ratings and control interfaces for the selected HCR or LSR machine | Document the required adapters or alteration scope and check connections before trial. |
| 5. Parting face, vents and flash | Close-up photos and recent parts showing flash, sticking or filling defects | Inspect for crushed or dented shutoffs, wear, blocked vents and previous repairs | Record findings and agree whether to clean, repair locally or rework inserts. |
| 6. Drawing revision and cavity history | Latest CAD and drawing, approved parts and limit samples, cavity map, compound and process record | Match revisions and identify each cavity, material grade and settings to reproduce on T1 | Resolve drawing or sample mismatches and hold cavity-specific defects for review. |
| 7. T1 trial after receipt | The last approved part and inspection sheet for comparison | Mark trial parts by cavity and compare dimensions, appearance and actual use | Sign off the sample or quote the correction and schedule another trial. |
Decide whether to repair first, run T1 or replace the tool
Repair before testing if inspection finds damage that would prevent safe mounting or closing, or if known defects can be traced to a worn surface or insert. Youbang's in-house five-axis CNC and EDM workshop can review feasible repair work. If the tool fits, the interfaces match and the parting faces are sound, use a controlled first trial to see what the transferred tool actually produces. Compare replacement tooling if the press interfaces need substantial changes or the part revision requires major cavity work.
For silicone baby bibs and placemats, compare each cavity's fastener and catch-pocket opening under the agreed load. Fit the mats to the target tray and check whether the corners lift after washing and drying. Use the old approved part as a comparison and record the trial settings and samples for the next approval decision.
What to send for a transfer review
Send the tool ID, measured envelope and weight, mounting and connection photos, the latest drawing and sample, a short defect list and your desired first-order quantity. Identify who owns the tool and who can authorize pickup. If the old factory still has the press and operators available, collect the latest setup and cavity notes while you can verify them. Request a mold transfer review with what you have.